Fluke 3125 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ochronniki przeciwprzepięciowe Fluke 3125. Fluke 3125 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
3125
Detachable Hot Plate
Users’ Manual
Rev. 622101
Hart Scientific
http://www.rongqe.cn/
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Users’ Manual

3125Detachable Hot PlateUsers’ ManualRev. 622101Hart Scientifichttp://www.rongqe.cn/

Strona 3 - Table of Contents

2 IntroductionHart Scientific’s Model 3125 Detachable Hot Plate is controlled by Hart Scien-tific’s 2200 controller and uses a precision platinum RTD

Strona 5 - 1 Before You Start

3 Specifications and EnvironmentalConditions3.1 SpecificationsTemperature Range 35°C to 400°C (95°F to 752°F)Display Accuracy ±0.5°C to 200°C±1.0°C to

Strona 6 - 1.2 Safety Information

•ambient relative humidity: maximum 80% for temperature <31°C, de-creasing linearly to 50% at 40°C•pressure: 75kPa-106kPa•mains voltage within ±10%

Strona 7 - Safety Information

4 Troubleshooting4.1 Troubleshooting Problems, Possible Causes,and SolutionsIn the event that the instrument appears to function abnormally, this sect

Strona 8 - Cautions

Problem Possible Causes and SolutionsThe display shows anyof the following:err 1,err 2,err 3,err4,Err 5,Err 6,orErr 7Controller problem. The error mes

Strona 9 - Authorized Service Centers

Limited Warranty & Limitation of LiabilityEach product from Fluke's Hart Scientific Division ("Hart") is warranted to be free from

Strona 10

Table of Contents1 Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 Symbols Used . . . . . . .

Strona 12

1 Before You Start1.1 Symbols UsedTable 1 lists the International Electrical Symbols. Some or all of these symbolsmay be used on the instrument or in

Strona 13 - Conditions

Symbol DescriptionCanadian Standards AssociationOVERVOLTAGE (Installation) CATEGORY II, Pollution Degree 2 per IEC1010-1 re-fers to the level of Impul

Strona 14

cautions. Before working inside the equipment, turn the power off anddisconnect the power cord.•Always replace the fuse with one of the same rating, v

Strona 15 - 4 Troubleshooting

1.2.2Cautions•DO NOT plug the unit into 230V if the heater switches and fuse holderread 115V. This action will cause the fuses to blow and may damage

Strona 16 - 4.2 Comments

NETHERLANDSPhone: +31-402-675300Telefax: +31-402-675321E-mail: [email protected] Int'l CorporationService Center - InstrimpexRoom 2301 Sc

Komentarze do niniejszej Instrukcji

Brak uwag