Fluke VICTOREEN 05-437 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Monitory Fluke VICTOREEN 05-437. Fluke VICTOREEN 05-437 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 20
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Victoreen
®
05-437
Primalert
®
35 Area Radiation Monitor
Operators Manual
March 2005
Manual No. 126011 Rev. 3
©2003, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - 35 Area Radiation Monitor

Victoreen® 05-437 Primalert® 35 Area Radiation Monitor Operators Manual March 2005 Manual No. 126011 Rev. 3 ©2003,

Strona 2 - 440.498.2564

Victoreen 05-437 Operators Manual 2-2 2.4 Optional Power The Primapak II storage battery supplies a source of 12-16 Volt DC power to the Primalert u

Strona 3 - Table of Contents

OperationSet Up3 3-1Section 3 Operation 3.1 Set Up The only set-up required for the Primalarm is the attachment of one end of the power cord (conver

Strona 4

Victoreen 05-437 Operators Manual (Blank page)

Strona 5 - Introduction

MaintenanceMaintenance4 4-1Section 4 Maintenance 4.1 Maintenance This instrument contains CMOS integrated circuits. No service should ever be atte

Strona 6 - 1.2 Specifications

Victoreen 05-437 Operators Manual 4-2 Table 4-2. PC Board Assembly (126021) Parts List Item No. Ref. No. Part No. Description Qty 6 V1 010054

Strona 7

MaintenanceMaintenance4 4-346 R22, 23 302041 Resistor, Film, 200k, .25W, 5% 2 47 R20, 26,30, 32,33,38, 341041 Resistor, Film, 100k, .25W, 5% 6 49

Strona 8

Victoreen 05-437 Operators Manual 4-4 Figure 4-1 Primalert 35 Assembly (126028)

Strona 9 - Getting Started

MaintenanceMaintenance4 4-5 Figure 4-2 Primalert 35 Schematic (126015)

Strona 10 - 2.6 Attaching a Ground Wire

Victoreen 05-437 Operators Manual 4-6 Figure 4-3 PC Assembly (126021)

Strona 12 - (Blank page)

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.256

Strona 13 - Maintenance

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.256

Strona 14

i Table of Contents Section 1: Introduction... 1-1 1.1

Strona 15

(Blank page)

Strona 16

IntroductionProduct Description1 1-1Section 1 Introduction 1.1 Product Description The Primalert® 35 Area Radiation Monitor provides reliable, conti

Strona 17

Victoreen 05-437 Operators Manual 1-2 1.2 Specifications Detector Energy-compensated G-M tube Energy Dependence 10% to 40% from 50 KeV to 2 MeV, a

Strona 18

IntroductionSpecifications1 1-3 Input 230 VAC, 50 Hz, 13.8 W Output 12 VDC, 580 mA Part 14-417, Part 14-416 (Australia) Dimensions 5.9 i

Strona 19

Victoreen 05-437 Operators Manual (Blank page)

Strona 20

Getting StartedReceiving Inspection2 2-1Section 2 Getting Started 2.1 Receiving Inspection Upon receipt of the unit: 1. Inspect the carton(s) and c